Sensor
Battery
Connector
Valve
Battery Clip
Service the Battery
CAUTION: Risk of product damage. Separate the connectors
by pulling gently while holding onto each connector. Do not
pull apart by the wires.
Perform the steps in the "Disassemble the Faucet" section.
Pull up on the spout to separate it from the valve.
Disconnect the battery connectors by pulling gently on both
connectors.
Reach inside the faucet body and gently pull the end of the
battery clip up until it comes free from the two tabs.
Pull the battery and battery clip out of the faucet body.
Remove the battery from the battery clip.
Install a new battery into the battery clip.
If the sensor clip comes out with the battery clip, reinstall it
according to the steps in the "Replace the Sensor " section.
Continue to the "Reinstall the Battery Clip - DC Models Only"
section.
Kohler Co.
Connector
Position 1
7
Connector
Position 2
1025498-5-H