AC24NE
LED Display
De nition
F16
Sensibilidad
Photocell Function Mode
FA
Pedestrian Mode
FB
Flashing Light
FC
Photocell Activation
FD
Photocell 2 Activation
FE
Alarm Buzzer
FF
Electric Latch Mode
FG
LED Direction
FH
Dual / Single Gate
FI
Parameter
Obstacle detection considered as
F16-0
overcurrent immediately.
Obstacle detection considered as
F16-1
overcurrent after 0.1 seconds.
Obstacle detection considered
F16-2
as overcurrent after 0.2
seconds.
F16-3
Obstacle detection considered
as overcurrent after 0.3
seconds
F16-4
Obstacle detection considered
as overcurrent after 0.4
seconds
F16-5
Obstacle detection considered
as overcurrent after 0.5
seconds
FA-1
Mode 1
FA-2
Mode 2
FA-3
Mode 3
FA-4
Mode 4
FB-0
Function OFF
FB-1
Function ON
FC-0
Function OFF
FC-1
Function ON
FD-0
Function OFF
FD-1
Function ON
FE-0
Function OFF
FE-1
Function ON
FF-0
Function OFF
FF-1
Function ON
FG-0
Standard Gate Opening
FG-1
Release Gate Tension before
Opening (Gate Reversing for 0.25s)
FH-0
For articulated arm
FH-1
For swing gate
FI-1
Single Gate
Dual Gate
FI-2
Table
1. The original parameter is "16-0"
1. Please see 7.3 photocell adjustment
for photocell logic
2. The factory setting is "FA-1"
1. El parámetro original es "FB-1".
1. When function FC-1, the light will
flash for 3 seconds
before the gate operates. If set OFF,
the flash light will
operate with motor at the same time.
2. The factory setting is "FC-0".
1. The factory setting is "FD-0".
1. The factory setting is "FE-0".
1. The factory setting is "FF-0".
1. If the function is FG-1, the motor will
be reversed for
0.25 sec. to release the tension.
2.The factory setting is "FG-1".
1. The factory setting is "FH-1".
1. The factory setting is "FI-2".
Opening your life
Description
1 21
loading