1
Antenna
2
Antenna shield
Opening control for the connection of control
3
devices with N.O. contact
Opening controls for pedestrian access for the
4
connection of control devices with N.O. contact
5
Stop command. N.C. contact
6
Common (-)
7
Photocells type 1. N.C. contact
8
Photocells type 2. N.C. contact
9
Safety ribbons type 1 (fixed). N.C. contact
10
Safety ribbons type 2 (mobile). N.C. contact
11
Common (-)
12
End of stroke in door 1 opening phase. N.C. contact
13
End of stroke in door 1 closing phase. N.C. contact
14
End of stroke in door 2 opening phase. N.C. contact
15
End of stroke in door 2 closing phase. N.C. contact
16
Common (-)
Power output 24 VAC for photocells and other
17 - 18
accessories
18 - 19
Photocell TX power supply for functional test
ELECTRIC CONNECTIONS TABLE
20 - 21
22 - 23
24
25
26
27
28
29
30
31
F1
OPTIONS
MAINS
OVERLOAD
FCC
FCA
OP
PA
CL
46
Electric lock 12VAC
Flashing light
230VAC 40W (City1) / 120VAC 40W (City1-120V)
Motor 2 opening
Motor 2 common
Motor 2 closing
Motor 1 opening
Motor 1 common
Motor 1 closing
Neutral 230 VAC / 120 VAC
Power phase 230 VAC / 120 VAC
5A (City1) / 8A (City1-120V)
Optional modules connector
It shows that the control unit is power supplied
It shows that there is an overload on accessories
power supply
It shows the opening end of stroke activation
It shows the closing end of stroke activation
Opening in progress
Pause (gate opened)
Closing in progress