Porter Cable PCC601 Manual De Instrucciones página 8

13mm taladro/destornillador inalámbricos de iones de litio de 20v max
Idiomas disponibles

Idiomas disponibles

recommended that the batteries be recharged after each use.
charger diagnostics
This charger is designed to detect certain problems that can arise with the battery packs
or the power source. Problems are indicated by one LED flashing in different patterns.
Bad Battery
The charger can detect a weak or damaged battery. The LED flashes in the pattern
indicated on the label. If you see this bad battery blink pattern, do not continue to
charge the battery. Return it to a service center or a collection site for recycling.
Hot/cold Pack delay
When the charger detects a battery that is excessively hot or excessively cold,
it automatically starts a Hot/Cold Pack Delay, suspending charging until the
battery has normalized. After this happens, the charger automatically switches
to the Pack Charging mode. This feature ensures maximum battery life. The light
flashes in the pattern indicated on the label.
Problem Power line
When the charger is used with some portable power sources such as generators
or sources that convert DC to AC, the charger may temporarily suspend
operation. The LED flashes in the pattern indicated on the label. This indicates
that the power source is out of limits.
leaving the Battery in the charger
The charger and battery pack can be left connected with the LED glowing indefinitely.
The charger will keep the battery pack fresh and fully charged. This charger features
an automatic tune-up mode which equals or balances the individual cells in the
battery pack to allow it to function at peak capacity. Battery packs should be tuned up
weekly or whenever the battery no longer delivers the same amount of work. To use
the automatic tune-up mode, place the battery pack in the charger and leave it for at least 8
hours.
Important charging Notes
1. Longest life and best performance can be obtained if the battery pack is charged
when the air temperature is between 65°F and 75°F (18°- 24°C). DO NOT charge the
battery pack in an air temperature below +40°F (+4.5°C), or above +105°F (+40.5°C).
This is important and will prevent serious damage to the battery pack.
2. The charger and battery pack may become warm to touch while charging. This
is a normal condition, and does not indicate a problem. To facilitate the cooling
of the battery pack after use, avoid placing the charger or battery pack in a warm
environment such as in a metal shed, or an uninsulated trailer.
3. If the battery pack does not charge properly:
a. Check current at receptacle by plugging in a lamp or other appliance
b. Check to see if receptacle is connected to a light switch which turns power off
when you turn out the lights.
c. Move charger and battery pack to a location where the surrounding air
temperature is approximately 65°F - 75°F (18°- 24°C).
d. If charging problems persist, take the tool, battery pack and charger to your
local service center.
4. The battery pack should be recharged when it fails to produce sufficient power
on jobs which were easily done previously. DO NOT CONTINUE to use under these
conditions. Follow the charging procedure. You may also charge a partially used pack
whenever you desire with no adverse affect on the battery pack.
Safety Warnings and Instructions: drills
WARNING
Before using tool, read all instructions and cautionary markings on tool.
:
WARNING
:
Drill may stall (if overloaded or improperly used) causing a twist.
Always expect the stall. Grip the drill firmly with two hands to control the twisting action
and prevent loss of control which could cause personal injury. If a stall does occur,
release the trigger immediately and determine the reason for the stall before re-starting.
operating Instructions
Installing and Removing the Battery Pack from the tool
8
loading

Este manual también es adecuado para:

Pcc601lbPcc601laPcc601lb-ca