OPERATING INSTRUCTIONS
Error codes and protection code:
E1- Room temperature sensor error-
Unplug the unit and plug it back in.
If error repeats, call for service.
E2- Evaporator temperature sensor error-
Unplug the unit and plug it back in.
If error repeats, call for service.
E3- Condenser temperature sensor error-
Unplug the unit and plug it back in. If error
repeats, call for service (on some models).
E4- Display panel communication error-
Unplug the unit and plug it back in.
If error repeats, call for service.
EC- Refrigerant leakage detection malfunction-
Unplug the unit and plug it back in.
If error repeats, call for service.
E7- Zero-crossing malfunction-
Unplug the unit and plug it back in. If error
repeats, call for service.
P1- Bottom tray is full - Connect the
drain hose and drain the collected
water away. If protection repeats, call
for service.
FOLLOW ME/TEMP SENSING feature(optional)
NOTE:This feature can be activated from the
remote control ONLY. The remote control
servesas a remote thermostat allowing for the
precise temperature control at its location.
To activate the Follow Me/Temp Sensing
feature, point the remote control towards
the unit and press the Follow Me/Temp
Sensing button. T
he remote display is
actual temperature at its location. The
remote control will send this signal to the
air conditioner every 3 minutes interval
until press the Follow Me/Temp Sensing
button again.
If the unit does not receive
the Follow Me/Temp Sensing signal during
any 7 minutes interval, the unit will beep to
indicate the Follow Me/Temp Sensing mode
has ended.
Operating Instructions
COOL operation
-
Press the "MODE" button until the "COOL"
indicator light comes on.
-
Press the ADJUST buttons "+" or " - " to
select your desired room temperature. The
temperature can be set within a range of
O
O
O
O
17 C-30 C/62 F-88 F (or 86 F).
-
Press the "FAN SPEED" button to choose the
fan speed.
7
O
HEAT operation
(cooling only models without)
-
Press the "MODE" button until the "HEAT"
indicator light comes on.
-
Press the ADJUST buttons "+" or " - " to
select your desired room temperature. The
temperature can be set within a range of
O
O
O
O
17 C-30 C/62 F-88 F (or 86 F).
-
Press the "FAN SPEED" button to choose
the fan speed. For some models, the fan
speed can not be adjusted under HEAT
mode.
DRY operation
-
Press the "MODE" button until the "DRY"
indicator light comes on.
-
Under this mode, you cannot select a fan
speed or adjust the temperature. The fan
motor operates at LOW speed.
-
Keep windows and doors closed for the
best dehumidifying effect.
-
Do not put the duct to window.
AUTO operation
-
When you set the a ir c onditioner i n A UTO
mode, it will automatically select cooling,
heating(cooling only models without), or
fan only operation depending on what
temperature you have selected and the
room temperature.
-
The air conditioner will control room
temperature automatically round the
temperature point set by you.
-
Under AUTO mode, you can not
select the fan speed.
FAN operation
-
Press the "MODE" button until the
"FAN " indicator light comes on.
-
Press the "FAN SPEED" button to
choose the fan speed. The temperature
cannot be adjusted.
-
Do not put the duct to window.
TIMER operation
-
When the unit is on, press the
Timer button will initiate the Auto-off
stop program, the TIMER OFF
indicator light illuminates. Press the
UP or downb utton t o s electth e d esired
time. Press the TIMER button again
within 5 seconds, the Auto-on start
program is initiated. And the TIMER
ON indicator light illuminates. Press
the up or down button to select the
desired Auto-on start time.
O