Periodic maintenance
After each operating period of approximately 150
impact hours or twice a year the machine must be
dismantled and all parts be cleaned and checked.
This work must be performed by authorized staff,
trained for this task.
1. Be sure that mating surfaces are clean and
smooth and that the bolts are tight.
2. Thoroughly clean and inspect internal parts and
make sure they are free from rust, grit and
foreign matter.
3. Thoroughly clean and inspect valve parts. Be
sure that the valve moves freely.
4. Make sure that striking faces on the anvil block
are parallel and flat. If the block is cupped, grind
off high edges but do not touch the polished
face where the anvil strikes the steel shank.
Maximum allowed wear (A)
illustration shown below.
A
Tightening torques
NOTICE
When fitting a claw coupling or other
connector to the swivel, Loctite® 263™(Loctite is a
registered trademark of Henkel Corporation. 263 is
a trademark of Henkel Corporation) or similar has
to be used.
9800 1352 90b | Original instructions
in. (1mm). See
1
32
Safety and operating instructions
Torque: CP 1260 S SPDR and CP 1290 S SPDR,
A.
100 lbf.ft (135 Nm).
B.
The cylinder seal must protrude approximately
1
in. (1.6 mm) before assembly of the back
16
head.
Torque: 150 lbf.ft (200 Nm). Apply Loctite®
C.
263™ (Loctite is a registered trademark of
Henkel Corporation. 263 is a trademark of
Henkel Corporation).
D.
Torque, Muffler 6–7 lbf.ft (8–10 Nm).
Assembled length of buffer.
E.
Model
CP 1260 S SPDR
CP 1290 S SPDR
A
B
C
D
E
Min-Max length
in. (mm)
2.14 -2.19 (54.4–55.6)
2,55 –2,61 (64,8–66,2)