GYS FLASH 51.12 CNT FV Manual De Instrucciones página 23

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 38
GYSFLASH 51.12 CNT FV / 101.12 CNT / 103.12 CNT / 121.12 CNT FV /
123.12 CNT FV / 125.12 CNT FV / 101.24 CNT FV / 103.24 CNT FV /
Restore the previous configuration:
This function allows you to restore the second to last charger configuration in case of a problem or error with the last downloaded
configuration.
1 Enter the "Restore CONFIG" submenu
2 Confirm the restoration of the configuration.
3 The charger will then restore the penultimate configuration of the charger.
Export charging data on USB stick:
This function allows you to retrieve the charge history and data on a USB key, in order to be able to use them on a spreadsheet or
other.
1 Enter the "Export DATA" submenu
2 Confirm the recording of the charging data.
3 The charger will then copy the charging data to the USB stick as files, « .CSV »
Custom configuration
List of modes and profiles available for customization:
CHARGE MODE
Charge
Charge
type:
profiles
normal
AGM
water
Easy
Pb-CHARGE
boost
recovery+
Ca/Ca recov
LFP/LiFePO4
Li-ion std
Li-CHARGE
LFP cell+
Li-ion cell+
25.48 CNT FV / 51.48 CNT FV / 53.48 CNT FV
Charging voltage
2.40 V/cell
Charging profile for lead batteries of the types Gel, MF, EFB, SLA...
Charging profile for most AGM lead-acid batteries including START and STOP.
2.45 V/cell
However, some AGM batteries require a lower voltage charge (Normal profile). Check the
battery manual if in doubt.
2.45 V/cell
Charging profile for open liquid-type lead-acid batteries with plug.
Charging profile dedicated to lead batteries that automatically adapts the charging current
according to the size of the battery.
2.40 V/cell
However, for maximum charge optimization, it is recommended, when possible, to use
normal, AGM or liquid charge curves.
Maximum current charge for lead-acid battery. This type of charge is ultra-fast.
2.42 V/cell
Warning : this type of charge must remain occasional in order to preserve bat-
tery life.
Charging profile for the recovery of severely damaged lead batteries. It is essential to
recover the battery outside the vehicle to avoid damaging the vehicle electronics and in a
2.40 - 2.50 V/cell
well ventilated area.
Caution: Recovery voltage up to 4.0 V/cell.
Charging profile for calcium battery recovery. The battery must be recovered outside the
2.45 - 2.66
vehicle to avoid damaging the vehicle's electronics and in a well-ventilated area.
V/cell
Caution: Recovery voltage can reach up to 2.75 V/cell.
3.60 V/cell
Charging profile for Lithium batteries type LFP (Lithium Ferro Phosphate)
Charging profile for standard lithium-ion batteries based on Manganese or Cobalt (NMC,
4.20 V/cell
LCO, LMO, MCO...)
Charging profile dedicated to LFP (Lithium Ferro Phosphate) type lithium-ion cells with
3.60 V/cell
selection of the number of cells in series to be charged.
Charging profile dedicated to standard lithium-ion cells based on Manganese or Cobalt
4.20 V/cell
(NMC, LCO, LMO, MCO...) with selection of the number of cells in series to be charged.
EN
Restore CONFIG
Continue?
YES
Loading
Export DATA
Continue?
Yes
Loading
23
23
loading