Before moving the range, protect any finished flooring and
secure oven door(s) closed to prevent damage.
Vent hood Combinations:
It is recommended that these ranges be installed in
conjunctionwith a suitable overhead vent hood.
Due to the high heat capacity of this unit, particular attention
should be paid to the hood and ductwork installation to assure
it meets local building codes.
A hood with suitable capture area and capable of at least
450 cfm is suggested to effectively evacuate odors, steam and
heat. Choosing to install a hood of lower cfm or configured for
recirculating may compromise the effectiveness of eliminating
the aforementioned factors.
Note: some State / Provincial building codes will require
make up air systems be installed for hoods above a
certain cfm threshold (300 cfm is typical).
It is your responsibility to understand and comply with
the local requirements for gas, electrical and ventilation
where these appliances are being installed.
WARNING
Air curtain or other overhead hoods, which operate
blowing a downward air flow on to a range, shall not be used
in conjunction with ranges with gas cooktop other than when
the hood and range have been designed, tested and certified
by an independent test laboratory for use in combination with
each other.
Clearances to horizontal surfaces above the range, measured
to the cooking surface are below. Failure to comply may
result in fire hazard.
• Installations without a hood require 48" (122) minimum
to combustibles.
• For other installations with a hood, refer to the hood
installation instructions for specific hood clearances.
CAUTION
These ranges weigh up to 400 pounds. Some disassembly
will reduce the weight considerably. Due to the weight and
size of the range and to reduce the risk of personal injury or
damage to the product:
TWO PEOPLE ARE REQUIRED FOR PROPER INSTALLATION.
Anti-Tip Bracket Installation
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Ensure the anti-tip bracket is engaged when the range is
moved.
Do not operate range without anti-tip bracket installed and
engaged.
Failure to follow these instructions can result in death or serious
burns to children and adults.
2 - Product Dimensions and Cutout Requirements
To verify the anti-tip bracket is installed and engaged:
• Slide range forward.
• Look for the anti-tip bracket securely attached to floor or wall.
• Slide range back so rear range foot is under anti-tip bracket.
• See installation instructions for details.
by
CABINET
SIDEWALL
FLUSH
For Concrete or Cement Construction:
You must use appropriate fastening hardware (not
provided).
Secure the bracket to the wall and/or floor with at least 4
wood screws (provided).
The anti-tip bracket should be inserted into the opening on
the anti-tip brace on the range.
WARNING
ANTI-TIP BRACKET INSTALLATION
BACKWALL
ANTI-TIP
BRACKET
EN
Anti-Tip Bracket
Range Foot
WALL
ANCHOR
5