Fulgor Milano F4PGR366S2 Instrucciones Para La Instalación página 19

Idiomas disponibles

Idiomas disponibles

Replace injector on (oven lower burner)
1. Remove the burner covers plate.
2. Remove the screw securing the oven burner and withdraw
the burner from the support.
6 - Conversion for LP or NG Gas
3. Remove the nozzle by turning 9-32" (7 mm) nut driver
counter clockwise.
4. Install the injectors supplied with this appliances in the
appropriate burner. The injectors have small number
stamped on the side, this number codes the orifice diameter
and its correct burner location (see figure of the paragraph
"Injectors position").
5. Turn clockwise to tighten (tighten to a torque of 15 to 20
inch-lbs)
6. Replace all parts following the reverse order. Save the
injectors removed from the appliances for future use.
EN
15
loading