Important Charging Notes - Bosch 11225VSR Instrucciones De Funcionamiento Y Seguridad

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

BM 1619929426 8/01
8/2/01
INDICATORS, SYMBOLS AND MEANING
If the indicator lights are "OFF", the
charger is not receiving power from
power supply outlet.
If the green indicator light is "ON",
the charger is plugged in but the
battery pack is not inserted, or the
battery pack is fully charged and is
being trickle charged.
If the green indicator light is
"BLINKING", the battery pack is
being fast-charged. Fast-charging
will automatically stop when the
battery pack is fully charged.
If the red indicator light is "ON",
the battery pack is too hot or cold
for fast-charging. The charger will
switch to trickle charge, until a
suitable temperature is reached, at which
time the charger will switch automatically to
fast-charging.
If the red indicator light is
"BLINKING", an acoustical signal
will sound for a period of 2 seconds
which indicates the battery pack
cannot accept a charge or the contacts of
the
charger
or
battery
contaminated. Clean the contacts of the
charger or battery pack only as directed in
these operating instructions or those
supplied with your tool or battery pack.
1. The battery pack accepts only about 80%
of its maximum capacity with its first few
charge cycles. However, after the first few
charge cycles, the battery will charge to full
capacity.
2. The charger was designed to fast charge
the battery only when the battery
temperature is between 32˚F (0˚C) and 140˚F
(60˚C). If the battery pack is too hot or too
cold, the charger will not fast charge the
battery. (This may happen if the battery pack
is hot from heavy use). When the battery
temperature returns to between 32˚F (0˚C)
and 140˚F (60˚C), the charger will
automatically begin charging.
3. A substantial drop in operating time per
charge may mean that the battery pack is
1:19 PM
Page 11
RED
LIGHT
pack
are

IMPORTANT CHARGING NOTES

nearing the end of its life and should be
replaced.
4. If you anticipate long periods (i.e. a month
or more) of non-use of your tool, it is best to
run your tool down until it is fully discharged
before storing your battery pack. After a long
period of storage, the capacity at first
recharge will be lower. Normal capacity will
be restored in two or three charge/discharge
cycles. Remember to unplug charger during
storage period.
5. If battery does not charge properly:
a. Check for voltage at outlet by plugging
in some other electrical device.
b. Check to see if outlet is connected to a
light switch which turns power "off" when
lights are turned off.
-11-