• Avoid body contact with ground potential (e.g. metallic terminals, output
sockets, lead clamp...) while measuring. Make sure to be electrically
insulated from ground during measurement.
• Calibration and repair must be performed by a qualified technician. Refer to
your local dealer.
4.
Features
• LCD display with automatic polarity indication
• data-hold function
• DCV (max. 600V) and ACV (max. 600V) measurements
• ACA (max. 1000A) current measurements
• max. Ø for conductor: 30mm
• resistance measurements: max. 40Mohm
• frequency measurements: max. 10MHz
• temperature measurements: -50°C to 1,000°C
• diode test, continuity test and backlight
• K-type thermocouple measuring range: from -20°C to 1,000°C
• optional probes (not incl.): SONDE890, SONDE8264
• duty cycle measurements : 0.5 to 99% @ pulse width of 100µs to 100ms
• capacitance measurement: max. 100µF
• safety: indoor use only (overvoltage Cat. II 600V)
5.
Overview
Refer to the illustration on page 2 of this manual
1 current clamp
2 clamp trigger
3 rotary function switch
4 data hold & backlight button
5 mode select button
6.
Operation
GENERAL
• When the range of the measured signal is unknown, start measurement
in auto-range mode, and then select range according to indicated value.
• The display shows "OL" when the present range limit is exceeded. Select
a higher range to continue measurement.
• Do not measure voltages > 600 V or current higher than 1000A. Never
turn the rotary function switch [3] during measurement.
• The device will go in sleep mode when no activity is detected for ±30
min.
• For all measurements: pressing the data hold button [4] freezes the
currently measured value until the data hold button [4] is pressed again.
The hold-mode is indicated by the word "HOLD" in the display.
• To switch on the backlight, press and hold the backlight button [4] for
about one second. To switch the backlight off, press and hold the
backlight button [4] again for ±1s. Note that the meter goes in HOLD
mode when switching the backlight on or off. Press the data hold button
[4] again to continue normal measurement.
• The meter starts in auto ranging mode. To select the range manually,
press the range button [7] (not for AC current, diode and continuity
measurements). To return to auto ranging, press and hold the range
button [7] for ±2 seconds.
00 (04/11/2008)
INIA011 (DCM267N)
6 Hz - % select button
7 range select button
8 LCD display
9 COM jack
10 V Ω °C/°F jack
4
®
Velleman