ENGLISH
LOCATION REQUIREMENTS
IMPORTANT:
O
conditioner will be installed. Make sure you have everything necessary for correct
installation.
THE LOCATION SHOULD PROVIDE:
• A grounded electrical outlet within 6 ft. (183 cm) of where the power supply cord exits the air
conditioner, for models:
HWR05XCM
• A grounded electrical outlet within 4 ft. (122 cm) of where the power supply cord exits the air
conditioner, for models:
HWE10XCN
NOTE: o
D not use an extension cord, plug adapter, surge protector or multi-outlet adapter.
• Free movement of air in the room to be cooled.
• A large enough opening for the air conditioner. (See Fig.1)
• The air conditioner must not be installed in a through-the-wall sleeve
or in a wall. It can only be installed in a double-hung window.
NOTE: The outside cabinet louvers must not be obstructed by bushes,
trees, etc. Air must be able to pass freely through the cabinet
louvers. (See Fig.2)
CABINET LOUVERS
WINDOW INSTALLATION
Window opening measurements: (See Fig.1)
A. Width
B. Height
PAGE 6
s b
r e
e v
all governing codes and ordinances. Check the location where the air
HWE06XCN
HWE08XCN
HWE12XCN
Fig. 2
HWR05XCM
HWE06XCN/HWE08XCN
22"-36"
13-3/8"
INSTALLATION REQUIREMENTS
HWE10XCN/HWE12XCN
25" - 36"
13-3/8"
Fig. 1
B-HEIGHT
A-WIDTH
AIR DISCHARGE
24-1/2" - 38"
14-9/16"