Operating instructions SATAjet 5000 B RP/HVLP (DIGITAL)
EN
9.6. Replace CCS (ColorCode-System)
The CCS for the individual marking of the spray gun can be exchanged
according to [10-6].
9.7. Replace spindle of round/flat fan control
[11-1], [11-2], [11-3]
The spindle has to be replaced when air leaks from the fan control or
when the fan control does not work.
1. Removing the old spindle
• Remove screw [11-1] (Torx T20)
• Remove knob [11-2]
• Unscrew spindle [11-3] with wrench (size 14)
• Make sure that the spindle pick-up is free of material and paint resi-
dues, remove residues and clean with solvent, if necessary
2. Installation and position of new spindle
• Screw in spindle [11-3]
• Place the knob [11-2] on hexagonal of spindle
• Hand-tighten screw [11-1] (Torx T20) in the knob - hold knob in the
position while tightening
9.8. Replacing the battery (DIGITAL)
• Exchange battery outside of explosive areas only!
• Strictly observe the safety instructions in chapter 6.4.2!
According to the intensity of use, the battery will last between 1 to 3
years. To exclude measurement errors, the display will be shut-off in case
of insufficient battery capacity. According to display and use, the battery
has to be exchanged within the following time frames:
Display:
Battery symbol
Exclamation marks (flashing)
Display "Lo
Screw in new battery compartment lid with pre-mounted sealing (Art. No.
213769 including battery) hand-tight and check function.
126
Warning! Risk of explosion!
b
" upon switching-on
4-5 weeks
2-3 weeks
<1 week
steps:
[12-1] and [12-2]