WINDOW REQUIREMENTS
1
• These instructions are for a standard
double-hung window. You will need to
modify them for other types of windows.
• The air conditioner can be installed
without the accordion panels if needed
to fit in a narrow window. See the
window opening dimensions.
• All supporting parts must be secured
to firm wood, masonry or metal.
• The electrical outlet must be within
reach of the power cord.
21" to 35"
(With accordion panels)
17
3
⁄
(Without accordion panels)
STORM WINDOW REQUIREMENTS
2
A storm window frame will not allow the
air conditioner to tilt toward the outside,
and will keep it from draining properly.
To adjust for this, attach a piece of wood
to the stool.
WOOD PIECES–
WIDTH: 2"
LENGTH: Long enough to fit inside the
window frame.
THICKNESS: To determine the thickness,
place a piece of wood on the stool to
make it 1/2" higher than the top of the
storm window frame.
Attach securely with nails or screws
provided by the installer.
1/2" higher
than frame
Storm
window
frame
Installation Instructions
12" min.
" min.
8
Wood
Stool
PREPARE THE WINDOW
3
Cut the window sash seal to the window
A
width and stick the adhesive side to the
bottom of the sash.
B
Mark the centerline of the sill. Measure
and mark the locations for the support
" from both sides of the
brackets 7
⁄
1
2
centerline.
C
Place 2 support brackets on the sill,
against the back edge of the stool with
their holes centered on each 7
Type B screw
Inside
Outside
Support
bracket
Attach them to the sill with one Type B
D
screw through each support bracket.
11
Window
sash seal
INSIDE
" mark.
1
⁄
2
Stool
Sill
Support
bracket