Setup and connection
26
à
Only operate the pump in accordance with the operating
parameters and operating conditions described in Chapter
3 Technical data [} 13].
à
Ensure the proper use of the pump (See Chapter 2.6.1
Proper use [} 10]).
à
Eliminate the possibility of improper use of the pump (see
Chapter Improper use).
à
Note and follow the safety instructions (see chapter 2
Safety [} 7]).
WARNING
Translation of Original Operating Instruction, KNF 121228-121397 04/23
Risk of pump head bursting due to ex-
cessive pressure increase
à
Do not exceed the maximum per-
missible operating pressure (see 3
Technical data [} 13]).
à
Monitor the pressure during opera-
tion.
à
If the pressure exceeds the maxi-
mum permissible operating pres-
sure of the pump: immediately
switch off the pump and remedy
the fault (see Chapter Trou-
bleshooting).
à
Only throttle or regulate the air or
gas quantity on the suction line to
prevent the maximum permissible
operating pressure from being ex-
ceeded.
à
If the air quantity or gas quantity on
the pressure line is throttled or reg-
ulated, make sure that the maxi-
mum permissible operating pres-
sure at the pump is not exceeded.
à
Ensure that the pump outlet is not
closed or restricted.
Diaphragm pump N035.18