14
Gas test button
Allows the gas circuit to be cleansed of impurities and
the carrying out of the appropriate preliminary gas pres-
sure and flow adjustments, without power on.
3.3 Programs screen
1
General
Allows the storage and management of 64 welding pro-
grams which can be personalised by the operator.
2
Program storage
Enter the "program storage" menu by pressing button
for at least 1 second.
Select the required program (or the empty memory) (5)
by rotating the encoder.
Program stored
Memory empty
Save all the current settings on the selected program by
pressing button
The storage of a new program on an already occupied
memory location requires cancellation of the memory
location by an obligatory procedure.
3
Program retrieval
Retrieve the 1st program available by pressing button
.
Select the required program by pressing button
Select the required program by rotating the encoder.
.
Only the memories location occupied by a program
are retrieved, while the empty ones are automatically
skipped.
3.4 Alarm codes
E01, E02, E03 Temperature alarm
E07
Wire feed motor supply alarm
E08
Blocked motor alarm
E10
Power module alarm
E11, E19 System configuration alarm
E12
Communication alarm (WF - DSP)
E13
Communication alarm (FP)
E14, E15, E18 Program not valid alarm
E16
Communication alarm (RI)
E17
Communication alarm (μP-DSP)
E20
Memory fault alarm
E21, E32 Data loss alarm
E22
LCD display alarm
E29
Incompatible measurements alarm
E30
Communication alarm (HF)
E38
Undervoltage alarm
E39, E40 System power supply alarm
E43
Coolant shortage alarm
E44
Gas shortage alarm
E48
Wire out alarm
.
31