Electrical installation
26
O P E R A T I N G I N S T R U C T I O N S | GTB20
0.6 ... 0.8 Nm
0.4 ... 0.5 Nm
0.8 ... 1.3 Nm
1
Figure 1: Tightening torque
See
table 3
and
table
4.
1
CAUTION
Please provide adequate strain relief externally for the cable if necessary. The back
cover must be completely sealed before operation.
Note the preferred direction of the object relative to the sensor, cf.
page
26.
Figure 2: Alignment of the sensor relative to the object direction
The sensors must be connected in a voltage-free state. The following information must
be observed, depending on the connection type:
Male connector connection: Pin assignment
Cable: Wire color
Terminal connection: Pin assignment
Terminal connection:
1.
Untighten the M3 screw on the back cover and remove the back cover.
< 0.4 Nm
see figure 2,
8026846.1GXN/2022-11-05 | SICK