Dometic GROUP WAECO VAS 581 001 Instrucciones De Uso página 114

Idiomas disponibles
  • ES

Idiomas disponibles

Service tasks
9.6
Changing the vacuum pump oil
!
WARNING!
Switch off the A/CServiceCenter and unplug it from the power supply
before opening the housing.
1. Before changing the oil, let the vacuum pump run for about 10 min-
utes (manually, via the menu).
The following steps may only be performed by qualified personnel.
2. Take off the front panel:
Undo the screws (D) on the control panel and lift it up. Then undo the
screws (E) on the bottom of the front panel and take it off.
3. Place a receptacle with a capacity of at least ½ litre under the
A/CServiceCenter. The oil from the vacuum pump flows through the
opening (I) in the base of the unit.