11. Disconnect the system components which cannot be flushed from
the refrigerant circuit. These components include:
– Compressor
– Line filter
– Fixed choke
– Collection containers
– Filter drying units
– Expansion valve
12. Connect the components for flushing to the service ports (13) and
(14) of the A/CServiceCenter using special adapters and in accord-
ance with the manufacturer's specifications to form a flushing circuit.
I
NOTE
Observe the guidelines on repairs from the vehicle manufacturer.
13. In the basic menu, use the cursor keys  or  to select
"Other selections":
14. Press ENTER to confirm.
15. Use the cursor keys  or  to select "Flushing":
16. If necessary, use the keypad (7) to enter the data and press ENTER
to confirm.
If no data is to be entered, press ENTER to switch to the next pro-
gram step.
17. Use the cursor keys  or  to select whether to flush the entire air
conditioning system or just individual components:
18. Press ENTER to confirm.
19. Follow the instructions in the display.
20. Before working on the vehicle air conditioner, a leak inspection must
be carried out. For the flushing process, the flushing circuit is filled
with a sample filling of refrigerant. The pressure in the air conditioner
must remain constant over a period of 5 minutes. Performing the
flushing process is only possible if this test has been passed
successfully.
EN
Short selection
Free selection
Other selections
ENTER-OK
Flushing
Reset scales.
Service.
ENTER-OK STOP-EXIT
Full flushing
Fast flushing
ENTER-OK STOP-EXIT
Operation
105