Parameter
Operating humidity
Storage temperature
Storage humidity
Maximum thermal output
Maximum operational altitude
Maximum non-operational altitude
Shock
Table 3. AC power requirements
Parameter
Power supply
Maximum current draw per system
Maximum power consumption
Typical power consumption
Table 4. DC power requirements
Parameter
Minimum and maximum input voltage range −40V, –72V DC, 5A Max
Maximum input current
Specifications
NOTE: Reduce maximum
temperature by 1°C/125 meters
(1°F/228 feet) above 950 meters
(3,117 feet).
5% to 85% (RH), non-condensing,
continuously
5% to 90% (RH), non-condensing, short
term
Short term is </= 1% of operational hours
per year.
–40° to 65°C (–40° to 149°F )
5% to 95%, non-condensing
S4112F-ON: 180W, 614 BTU/hr
S4112T-ON: 200W, 682 BTU/hr
10,000 feet (3,048 meters)
39,370 feet (12,000 meters)
Dell EMC Spec SV0115
Specifications
100–240 VAC 50/60 Hz
2A/1.7A at 100/120V AC 1A/0.8A at
200/240V AC
S4112F-ON: 180 W
S4112T-ON: 200 W
S4112F-ON: 90 W
S4112T-ON: 120 W
Specifications
−40V/5A, −48V/4.2A, −72V/2.8A