1. Open the door; see the following figure.
2. Remove the fire-resistant inner plates; see the fol-
lowing figure.
a. Remove the fire basket (6).
b. Raise the baffle plate (5) at the front, pull the
baffle plate 2 cm forwards and allow the baffle
plate to drop down at the back
c. Remove the inner plates on the left and right
sides (4).
d. Remove the inner plates on the back (3).
Cast iron inner plates protect the com-
bustion chamber and dissipate heat to the
surroundings.
5
3
4
2
6
1
7
Removable internal sections
1 bottom of the fire compartment
2 ash removal port
3 back inner plate on the left and right
4 inner plate on the left and right side
5 baffle plate
9
09-20008-002
3
4
09-20008-004
6 fire basket
7 ashtray
Connecting to the rear
1. Apply supplied fibre glass sealing tape (2) meas-
uring 10 x 3 mm to the contact surface of the con-
nection collar (8).
2. Remove the protection plate from the back shield
with the assistance of a screwdriver; see following
figure.
3. Remove the cover from the back wall.
4. Install the connection collar to the back wall with
the materials.
5. Install the cover (1) with mounting bracket (4) in
the top plate.
Subject to change because of technical improvements.
09-20008-005