MD 9231 Industrial TRMS AC/DC Current Clamp Meter
ELECTRICAL SPECIFICATIONS
Accuracy is ±(% reading digits + number of digits) or otherwise specified, at 23 C ± 5 C.
Maximum Crest Factor < 2.5 : 1 at full scale & < 5 : 1 at half scale or otherwise specified, and with frequency
spectrum not exceeding the specified frequency bandwidth for non-sinusoidal waveforms.
DC Voltage
RANGE
600,0 V, 1000 V
Input Impedance: 10M, 100pF nominal.
AC Voltage (with Digital Low-Pass Filter
RANGE
50 Hz ~ 60 Hz
600,0 V, 1000 V
20 Hz ~ 200 Hz
600,0 V, 1000 V
200 Hz ~ 400 Hz
600,0 V, 1000 V
Input Impedance: 10M, 100 pF nominal.
DC+AC Voltage (with Digital Low-Pass Filter)
RANGE
50 Hz ~ 60 Hz
600,0 V, 1000 V
DC, 40 Hz ~ 200 Hz
600,0 V, 1000 V
200 Hz ~ 400 Hz
600,0 V, 1000 V
Input Impedance: 10 M, 100 pF nominal.
PEAK-rms (ACV & ACA)
Response: 80 ms to > 90%.
CREST (Peak-Hold)
Accuracy: Add 250 digits to specified accuracy for changes > 5 ms.
Audible Continuity Tester
Audible Threshold: At between 10 and 250 .
Response time: 32 ms approx.
Ohm
RANGE
600,0 , 6.000 k, 60,00 k
Open Circuit Voltage: 1,0 VDC typical.
mode for inrush current; 5ms Crest (Instantaneous Peak-Hold) mode;
Relative-Zero.
Accuracy
0.8% + 5d
Accuracy
0.8% + 5d
1.5% + 5d
10% + 5d
Accuracy
1.0% + 7d
1.8% + 7d
12% + 7d
Accuracy
1.0% + 5d
18
Specification