CONFIGURATION OF THE PARAMETERS

MODIFICATION OF THE PRESSURE OF THE SET

To increase by 0.1 bar
press both the keys at the same time
To decrease by 0.1 bar
press both the keys at the same time

VISUALISATION OF THE FUNCTION PARAMETERS

• To visualise the parameters on the display whilst it is functioning scroll with the keys
• By pressing the key
DISPLAY
DESCRIPTION
SYSTEM PRESSURE
P 3.2
Measured pressure of the system
WORK FREQUENCY
F 45
Immediate frequency of operation of the motor
ABSORBED CURRENT
A 6.5
Immediate current absorbed by the motor – ATTENTION: RMS value:
the reading of the electric current entering and exiting from the inverter, registered by normal
measuring instruments (eg. amperometric clamp), could be incorrect.
TEMPERATURE OF POWER MODULE
Tm 50
Temperature of the electronic power module of the inverter

VISUALISATION OF THE FIRMWARE VERSION (FW)

In order to visualise the FIRMWARE (FW) version of the INTERFACE (FWI) card and the POWER (FWP) card:
• Take the TISSEL-200 OUT OF SERVICE (OFF) by pressing the
• Press both the keys at the same time
34
| ENGLISH
one returns to the visualisation of the pressure of the system on the display.
+
example:
+
example:
key
P 3.2
P 3.3
P 3.2
P 3.1
U.M.
bar
Hz
A
°C