START UP
PRIMING OF THE PUMP
• Before switching on read the attached manual and follow the instructions, in order to avoid errors in settings and operations
which could cause anomalies in functioning.
• Do not switch on the pump when it is dry, not even for a few seconds.
• Before switching on the pump, prime the pump.
• Insert the plug in the socket.
• Press the switch (1) and wait for it to START (about 10 seconds).
• After 10 seconds the STARTING phase ends and TISSEL-200 returns to the same operating conditions which it was in when it
was last switched off:
– IN SERVICE if when it was last switched off it was IN SERVICE.
– OUT OF SERVICE if when it was last switched off it was OUT OF SERVICE (OFF).
In the case of an accidental fall in power, if TISSEL-200 was IN SERVICE (ON), when the power returns it will automatically
return to IN SERVICE (ON).
• To put TISSEL-200 in service press the key (2) ON/OFF on the control panel.
• TISSEL-200 starts to function.
• If the pump is not correctly primed place Tissel-200 into the TEST mode (manual control) and gradually open the delivery
valve (for its functioning in TEST mode see the respective chapter later in this manual).
ATTENTION: the inverter is perfectly configured in accordance with the predefined factory settings, in order to
function correctly with the associated pump.
If it were necessary to modify the factory settings of the TISSEL-200 set the inverter using the parameters in the HIDDEN LIST (see
chapter SETTING UP PARAMETERS IN THE HIDDEN LISTS).