4. LCD Display Operating Instructions
NO.
Item
06
Charging Mode
07
Maximum charging current
08
Battery Type
09
Increase charging voltage
Increases the maximum load
10
time
11
Float voltage
12
Discharge Surge
Configuration Options
[06] OSC
[06] CUB.
[06] Default value of SNU
[06] OSO.
[07] 80A default
[08] USO
[08] SLd
[08] LFd
[08] GEL
[08] LF14/LF15/LF16.
[08] N13/N14.
[09] 57.6V Default
[10] 120 Default
[11] 55.2V Default
[12] 42V Default
78
Description
Photovoltaic power is charged first, and network
charging is only activated when photovoltaic power is
Invalid.
The network is charged first, and photovoltaic charging
starts only when the network is invalid.
Combined charging of photovoltaic and grid power,
priority to photovoltaic charging, when photovoltaic
power is insufficient, the network charging supplement.
When the photovoltaic energy is sufficient, the electric
power stops charging. Note: Only when the bypass
output of the grid is charged, the PV network and the
power grid can be charged at the same time. When the
inverter is running, only photovoltaic charging can be
Initiated.
Photovoltaic charge only, do not start charging the
Network.
S series models, the adjustment range is 0~140A; U
series models, the adjustment range is O~120A.
User-defined, all battery parameters can be set.
Lead-acid sealed battery, 57.6V constant charging
voltage, 55.2V floating charging voltage.
Open lead-acid battery, 58.4V constant charging
voltage, 55.2V floating charging voltage.
Gel lead acid battery, 56.8V constant charging
voltage, 55.2V floating charging voltage.
LiFePO4 LF16/LF15/LF 14 battery, corresponding to 16
series, 15 series and 14 series lithium iron phosphate
battery, 16 series default constant charge voltage, 15
series default constant charge voltage, 15 series default
constant charge voltage, 14 series default constant
charge voltage, 49.2V voltage, adjustable.
Lithium battery terna, adjustable. The default constant
voltage charging voltage of N13 is 53.2V, and the
default constant voltage charging voltage of the N14
chain is 57.6V.
Improve charging voltage setting, the adjustment range
is 48V~58.4V, the step is 0.4V, and it is valid when the
battery type is customized and lithium battery.
Increase the setting of the maximum charge time, which
means that the voltage reaches the maximum charge
time of the parameter [09] voltage set when the constant
voltage charge, the adjustment range is 5min~900min,
and the step is 5 minutes.
Floating Voltage, Adjusting Range 48V~58.4V, Step 0.4V
Excessive discharge voltage, the battery voltage is
lower than the judgment point, the inverter output will be
turned off after the time set by the delay parameter [13],
the adjustment range is 40 V ~ 48 V, and the step is 0.4
V.