2.3 Conexión por cable
AC- input/output wiring method:
1. Before connecting the AC input/output, disconnect the external circuit breaker and confirm that the cables used are thick
enough. Refer to chapter "2.2 Wiring Specifications and Circuit Breaker Selection".
2. Connect the AC input cable properly according to the sequence of wires and terminal locations shown in the following figure.
Connect the ground cable first, then connect the active cable and the neutral cable.
3. Connect the AC outlet cable properly according to the cable sequence and terminal position shown in the following figure.
Connect the ground cable first, then connect the active cable and the neutral cable. The ground cable is connected to the
ground bolt hole of the battery housing through the type O terminal.
Note: The ground cable must have a thick diameter (the area of the cross section of the cable must not be less than 4 mm2). The grounding point should
be as close to the all-in-one machine as possible, and the shorter the ground cable, the better.
2. Installation Instructions
E:L ground cable:N active cable:Neutral cable
E:L ground cable:N active cable:Neutral cable