Refer to the form below for the size of the PV input cable and switch
Model
HOME KIT 1
HOME KIT 2
Note: The series voltage shall not exceed the maximum voltage of the PV input open circuit.
Refer to the following form for the size of the AC input cable and switch
Model
HOME KIT 1
HOME KIT 2
Note: There is a corresponding circuit breaker in the main inlet joint, and there is no need to add the circuit breaker.
Please refer to the form below for the size of the AC output cable and circuit breakers:
Model
HOME KIT 1
HOME KIT 2
Note: Thread size is for reference only. If the distance between the PV array and the all-in-one machine is long, using a thicker cable can reduce voltage
drop and improve system performance.
Note: The above cable size and circuit breaker are only recommendations, select the appropriate cable size and circuit breaker according to the actual
situation.
2. Installation Instructions
Recommended
PV Input
cable size
10mm2/7AWG
10mm2/7AWG
Recommend
ed CA input
cable size
10mm2/7AWG
10mm2/7AWG
Recommend
ed CA input
cable size
10mm2/7AWG
10mm2/7AWG
Max. PV
input current
50 A
50 A
Maximum inlet
current bypass
40 A
40 A
Maximum inlet
current bypass
40 A
40 A
54
Recommended air
switch or circuit
breaker model
2P: 63 A
2P: 63 A
Recommended air
switch or circuit
breaker model
2P—40 A
2P—40 A
Recommended air
switch or circuit
breaker model
2P—40 A
2P—40 A
loading