Residual current circuit breaker (RCD)
The amperage of the residual current circuit
breaker must correspond to the amperage of the
wallbox.
Installation: In accordance with IEC 60364
Standard installation: Type A with a rated current
of 25 A or 40 -A and maximum AC leakage current
detection of 30 mA
EV-ready installation: Type A+ (high resistance to
interference)
The wallbox is equipped with an internal DC leakage
current detector with tripping times and limit values
as -perIEC 61851-1:2017 (in conformity with IEC
62955:2018)
Installing the wallbox on the wall
a
(a) - Minimum clearance = 300 mm
(b) - Installation height = 800 mm to 1220 mm
(8) - Plug, 8 x 65 mm
(9) - Washer
(10) - T20 screw, 6 x 70 mm
Fasten the wall bracket to a suitable wall as shown.
a
a
b
- 10 -
8
10 9
M+P-03F-9913