Lifting arm booms, lifting arm bolts, carrier plate threaded bolts are to be
checked for ease of running. If required, lightly grease with multi-purpose
grease. Do not over-lubricate.
Version with MINI-MAX lifting
arm
1. Blow out and spray bolts. Check the
rollers for wear.
2. Check the locking screws (this is
only screwed in lightly and is then
glued (Loctite)). Screws may not be
completely tightened otherwise the
ease of running of the Mini-Max
mechanism is no longer guaran-
teed.
3. Clean and spray this frictional sur-
face. „Penetrating oil" similar to Top
2000 from Autol.
4. Check the safety plate for damage
and exchange if required.
Check all fastening screws and anchors with a torque wrench.
Fastening class 8.8
0.08*
0.12**
0.14***
M8
17.9
23.1
25.3
M10 36
46
51
M12 61
80
87
M16 147
194
214
M20 297
391
430
M24 512
675
743
Fastening class 10.9
0.08*
0.12**
0.14***
M8
26.2
34
M10 53
68
75
M12 90
117
128
M16 216
285
314
M20 423
557
615
M24 730
960
1060
*
Lubricated slide friction number 0.8 MoS2
**
Lightly oiled slide friction number 0.12
***
Ensured slide friction number 0.14 screw with micro-encapsulated plastic
All weld seams must have a visual inspection. Stop the system and contact the
manufacturer if there are cracks or breaks in weld seams of the lift.
Maintenance plan