2. Installation location
B
Fig. 2-1
3. Installing the indoor unit
1
2
4
5
7
8
0
q
Fig. 3-1
I A24, A30
A
38-31/32
13/32×3-19/32= (35-13/16)
35-7/16
23/32
23/32
B
D
E
8-27/32
9-7/16
7-3/32
7-3/32
F
H
I A36
G
50
1/2×3-19/32=(46-9/16)
23/32
23/32
D
B
E
11-5/8
8-27/32
9-71/16
H
F
Fig. 3-2
A
C
Fig. 3-3
A
D
E
W
3
6
9
9-21/32
17-29/32
11-7/32
3/4
3-19/32
G
C
11-1/32
12-3/8
24-1/32
3-17/32
I
A
9-21/32
23-7/16
11-7/32
35-7/16
3/4
3-19/32
C
7-3/32
11-1/32
12-3/8
29-17/32
3-17/32
H
I
B
E
D
2.1. Outline dimensions (Indoor unit) (Fig. 2-1)
Select a proper position allowing the following clearances for installation and mainte-
nance.
C
H
Models
W
1400
A24, A30
55-1/8
1680
A36
F
66-5/32
Warning:
Mount the indoor unit on a ceiling strong enough to withstand the weight of the
unit.
2.2. Outline dimensions (Outdoor unit)
Refer to the outdoor unit installation manual.
3.1. Check the indoor unit accessories (Fig. 3-1)
The indoor unit should be supplied with the following accessories.
PARTNUMBER
1
Wall-fixing bracket
Tapping screw 4 × 35
2
3
Insulation material
4
Band
5
Felt tape
6
Drain socket
7
Wireless remote controller
8
Remote controller holder
9
Alkali batteries
0
Wired remote controller
q
Drain adaptor
7 7 7 7 7 - 9 9 9 9 9 are stored in a cut-out section of the packing material (styrofoam).
(inch)
3.2. Installing the wall mounting fixture (Fig. 3-2)
1) Setting the wall mounting fixture and piping positions
s Using the wall mounting fixture, determine the unit's installation position
and the locations of the piping holes to be drilled.
Warning:
Before drilling a hole in the wall, you must consult the building contractor.
A Indoor unit center line
B Left drain range
C Right drain range
D Hole for tapping screw
E Bolt hole
F Hole for tapping screw
G Contour of the unit
H Knockout hole for left rear piping
I Rear piping access hole (90-100 mm, 3-9/16 to 4 inch dia.)
2) Drilling the piping hole (Fig. 3-3)
s Use a core drill to make a hole of 90-100 mm, 3-9/16 to 4 inch diameter in the
wall in the piping direction, at the position shown in the diagram to the left.
s The hole should incline so that the outside opening is lower than the inside
opening.
s Insert a sleeve (with a 90 mm, 3-9/16 inch diameter and purchased locally)
through the hole.
Note:
The purpose of the hole's inclination is to promote drain flow.
A Sleeve
B Hole
C (Indoors)
D Wall
E (Outdoors)
D
H
A
B
C
235
340
Min. 150
Min. 50
Min. 30 Max. 250 Max. 150
9-1/4
13-3/8 Min. 5-15/16
Min. 2
Min. 1-3/16 Max. 10 Min. 5-15/16
235
340
Min. 150
Min. 50
Min. 30 Max. 250 Max. 150
9-1/4
13-3/8 Min. 5-15/16
Min. 2
Min. 1-3/16 Max. 10 Min. 5-15/16
ACCESSORY
QUANTITY
1
12
2
4 (large) + 5 (small)
3
1
1
1
2
1
1
(mm)
(inch)
E
F
LOCATION OF SETTING
Fix at the back of the unit
Set inside the unit
}
for PKA-A·FAL
for PKA-A·FA
3
loading