Dip 1 - OFF
Enable forced closing on Power ON
Dip 1 - ON
Disable forced closing on Power ON
Dip 2 - OFF
Enable the wind speed function
Dip 2 - On
Disable the wind speed function
Dip 3 - OFF
Dip 4 - OFF Wind speed 20 km/hour
Dip 3 - OFF
Dip 4 - ON
Dip 3 - ON
Dip 4 - OFF Wind speed 42 km/hour
Dip 3 - ON
Dip 4 - ON
With a windspeed sensor installed you may program automatic closing in strong wind conditions.
The dip-switch "D1" (fig. 2) has four settings: 20-35-42 and 50 km/hour. When the anemometer is
active (strong wind conditions with jumper J4 inserted) control via the transmitter or via cable will
be excluded for 10 minutes. To calibrate the sensitivity level during installation you can override this
block by switching the power off and on again: however in this case you are advised to temporarily
deactivate automatic reclosing (Dip 1 "ON").
Dip-switch settings for the windspeed sensor
Wind speed 35 km/hour
Wind speed 50 km/hour
19