Electrical connection (fig. 1)
Before connecting the device to the mains make sure that:
- the voltage and frequency rated on the data plate conform to those of the mains supply;
- an all pole circuit breaker which leaves at least 3 mm between the contacts has been installed between
the device and the mains;
- the high voltage 230V wires pass through the holes marked "A" and are routed separately from the low
voltage wires which pass through the holes marked "B";
- the wires are fastened down using a cable clamp.
Caution: only low voltage circuits may be wired to the external circuit binding posts 1...6.
1
Outer conductor for radio receiver antenna
2
Inner conductor for radio receiver antenna with a 17 cm piece of rigid wire (if an external antenna is
fitted use a coaxial type cable RG58 with an impedance of 50Ω)
3
Anemometer input
4
Common for all inputs
5
Closing button input (N.O.)
6
Opening button input (N.O.)
7
Motor output (closing)
8
Motor output (opening)
9
Motor output (neutral)
10-11 Power supply 230 Vac 50-60 Hz
12
Power supply earth connection
13
Motor output earth connection
P1
D1
3
1
2
4
L2
B1
M1
CODES
1
2
3
ANEM
B
15
Pos.1 Pos.2
J1
J2
J3
J4
ON
J1 J2 J3 J4
J5
4
5
6
7
TC
TA
B
CS1488
DC0565
L1
F3.15A
8
9
10 11
c
M
L
N
A
1