- Directly connect devices with a cable or plug. In France, a product with plug is strictly
prohibited and cannot be installed.
- Always connect the earth conductor of the cable to the earth ground wire or connect the
earth conductor to the appropriate terminal identified by the symbol
is compulsory for safety reasons. The earth wire green - yellow must be longer than those
of phases. The installation must be equipped, upstream of the appliance, with a bipolar
cut-out device (minimum contact distance of 3 mm fuse, breaker switch). In the case where
hydraulic connexions are in insulated material, electrical circuits shall be protected by
a differential circuit breaker 30 mA adapted to local standards.
Thermal circuit breaker (see drawings section 3 page 87): All our products are
equipped with a thermostat with thermal circuit breaker and manual resetting which cuts off the
power supply to the water heater in case of overheating.
If the safety trips, switch off the power and reset the thermal circuit breaker
If the circuit breaker keeps tripping, remove cover check electrical connections and replace
the thermostat. Never short circuit the safety cut out or the thermostat. Connect the power
supply only via the terminal
SET-UP & OPERATION
EN
CAUTION!
NEVER POWER THE WATER HEATER WITHOUT WATER:
-
Models with an electric heating element will be certainly damaged.
- Fill the tank completely. Before powering up, open the hot water taps, drain the pipes in
order to empty the air.
- Check the tightness of the tubes and of the flange seal under the plastic cover. In case of leaking
tighten moderately. Check the operating of the hydraulic components and of the safety valve.
- Turn the power on. After 15 to 30 minutes, depending on the capacity of the device, the
water should drip from the drain. This is normal and due to the expansion of water. Check
connection leaks and seal. During heating and according to the water quality, hot water tanks
can make a bubbling noise. This noise is normal and does not indicate any defect of the unit.
MAINTENANCE
EN
CAUTION!
-
Before removing the plastic cover, make sure the power is turned off to
avoid any risk of injury or electric shock.

1. USER MAINTENANCE

Operates once a month the discharge of the safety valve to prevent scaling deposit and verify that
the safety device is not blocked. If this is not done, damage may be caused and the guarantee
invalidated. For an installation with a booster pump; before starting up, after a long period of
disuse, turn the rotor following the advice in the manufacturer's instructions.
2. MAINTENANCE BY A QUALIFIED PERSON
- Scaling: Remove the scale sludge. Do not scrape or hammer the lime scale deposited on
the casing, as this may damage the lining.
- Magnesium anode: change the magnesium anode every 2 years or when its diameter is
lower than 10 mm.
.