item of equipment is purchased, and selective collection by an
approved organisation. For further information, you can contact
your local supplier or local authority. Proper removal of waste
electrical and electronic equipment ensures proper processing
and repurposing, thus avoiding damage to the environment
and harm to human health, and protecting natural resources.
19. This product is intended for use at a maximum altitude of 2000 m.
EN
20. Always connect the earth conductor of the cable to the earth
ground or connect the earth conductor to the appropriate
terminal identified by the symbol
21. The instruction book of this product is available by contacting
the after-sales service (page 79).
22. See installation diagram (pages 82-83).
23. Above 50°C, water could cause immediate serious scalds.
Check the water temperature before taking a bath or shower.
24. Before removing the plastic cover, make sure the power is
turned off to avoid any risk of injury or electric shock.
EN
1. PRODUCT MOUNTING See "General Warnings" N°.1 to N°.6
For product installation, refer to drawings section 1 pages 82-83.
2. HYDRAULIC CONNECTION See "General Warnings" N°.10 to N°.14
For hydraulic connection, refer to drawings section 2 pages 84-86.
- It is necessary to clean the supply piping prior to the hydraulic connection. The connection to
the hot water outlet and the cold water inlet is to be carried out with a dielectric connector,
to avoid corrosion of the pipe (direct contact iron / copper). The installation must have a
pressure reducer if the supply pressure is over 0.5 MPa (5 bar). The pressure reducer must be
fitted at the main distribution outlet A pressure of 0.3 to 0.4 Mpa (3 to 4 bar) is recommended
- Always install a new safety device on the cold water pipe of the water heater, which comply
with the standards (EN 1487 in Europe), with a maximal pressure of 0.7 or 0.8 MPa (7 or 8 bar)
according to the nominal pressure, with diameter 1/2".
3. ELECTRICAL CONNECTION
For electrical connection, refer to drawings section 3 page 87.
- The water heater can be connected and operated only on AC 220-240 V~. Connect the heater
with a rigid cable with conductors 2,5 mm². Use a standardised channeling (rigid or flexible
conduit) until the calibrated housing cover.
INSTALLATION
.
76