Mitsubishi Electric MXZ-2C20NAHZ3 Manual De Instalación página 4

Idiomas disponibles

Idiomas disponibles

1 - 5 . I N S T A L L A T I O N D I A G R A M
Open as a rule
More than 19-11/16
in. (500 mm) if the
front and both sides
are open
More than
e n
3-15/16 in.
(100 mm)
Open as a rule
More than 19-11/16 in. (500 mm) if the
back, both sides and top are open
6-7/8
Air inlet
2 - (15/32 × 1-13/32)
oval holes (Base bolt M10)
2 . O U T D O O R U N I T I N S T A L L A T I O N
2 - 1 . I N S T A L L I N G
• Be sure to fix the unit's legs ith bolts hen installing it.
• Be sure to install the unit firmly to ensure that it does not fall by an earthqua e or a gust.
• Refer to the figure in the right for concrete foundation.
• In case of MXZ-2C20NAHZ3, MXZ-3C24/30NAHZ3, do not use the drain socket and the drain caps.
• In case of MXZ-5C42NA3, do not use the drain socket and the drain caps in the cold region. Drain may freeze and it makes the fan stop.
Make the setting
depth deeper.
3
More than 3-15/16 in. (100 mm)
More than 7-7/8 in. (200 mm)
if there are obstacles to both
sides
More than 13-25/32 in.
(350 mm)
O u t d o o r u n i t i n s t a l l a t i o n
2-U-shape notched holes
37-13/32
(Base bolt M10)
23-5/8
Air inlet
Air outlet
T H E U N I T
Fix here w ith
M10 bolts.
Make w ith w ider.
After the leak test, apply insulat-
ing material tightly so that there
is no gap.
When the piping is to be attached to
a w all containing metals (tin plated)
or metal netting, use a chemically
treated w ooden piece 25/32 in. (20
mm) or thicker betw een the w all
and the piping or w rap 7 to 8 turns
of insulation vinyl tape around
the piping.
To use existing piping, perform
COOL operation for 30 minutes
and pump do n before removing
the old air conditioner. Rema e flare
according to the dimension for new
refrigerant.
Units should be installed by licensed contractor according to
local code requirements.
175
Air inlet
2 - 12 × 36
Unit : inch
oval holes (Base bolt M10)
Anchor leg
Anchor bolt length
P A R T S T O
B E P R O V I D E D A T Y O U R S I T E
(A) Pow er supply cord*
(B) Indoor/outdoor unit connecting w ire*
(C) Extension pipe
all hole cover
(D)
(E) Piping tape
Extension drain hose (or soft PVC
(F)
hose, 19/32 in. (15 mm) inner
diameter or hard PVC pipe VP16)
(G) Refrigeration oil
(H) Putty
(I) Pipe fixing band
(J) Fixing screw for (I)
all hole sleeve
(K)
* N o t e :
Place indoor/outdoor unit connecting w ire (B) and
pow er supply cord (A) at least 3 ft. (1 m) aw ay from
the TV antenna w ire.
The
'ty for (B) to ( ) in the above table is quantity
to be used per indoor unit.
O u t d o o r u n i t i n s t a l l a t i o n
950
2-U-shape notched holes
(Base bolt M10)
600
Air inlet
Air outlet
23-5/8
(600)
Anchor bolt pitch
(Unit: inch (mm))
1
1
1
1
1
1
Little
amount
1
2 to 7
2 to 7
1
Unit : mm
loading

Este manual también es adecuado para:

Mxz-3c24nahz3Mxz-3c30nahz3Mxz-5c42na3