PYD Electrobombas PYD Serie Manual De Instalación Y Mantenimiento página 37

Idiomas disponibles

Idiomas disponibles

OPERATING AND MAINTENANCE MANUAL
PYD SERIES SOLAR INVERTER
Parameter
Explanation
A1-00
Activation of "solar mode
A1-01
Voltage selection Vmpp
Manual setting value of the
A1-04
open-circuit voltage VOC
A1-19
Voltage sleep level
A1-20
Voltage wake-up level
A1-21
Wake-up delay time
Weak light frequency
A1-22
detection
A1-23
Weak light detection time
A1-24
Weak light wake-up time
Under-consumption intensi-
A1-25
ty detection
Under-consumption detec-
A1-26
tion time
Underconsumption restart
A1-27
time
Maximum water level
A1-28
detection time
Maximum water level reset
A1-38
time
Minimum water level detec-
A1-39
tion time
Minimum water level reset
A1-40
time
www.proindecsa.com / [email protected]
Configurations
0: Enabled
1: Deactivated
0: Manual setting 1
1: Automatic MPPT algorithm
tracking
0.0~1000.0V
0.0~1000.0V
0.0~1000.0V
0~30000s
0.00~100.00Hz
0~30000s
0~30000s
0.00~300.00A
0~30000s
0~30000s
0~30000s
0~30000s
0~30000s
0~30000s
37
Configuration
Value to
factory
settings
adjusted
According to
1
model
According to
1
model
According to
500.0V
model
According to
360.0V
model
According to
400.0V
model
According to
60s
model
According to
15.00Hz
model
According to
30s
model
According to
60s
model
According to
0.00A
model
According to
60s
model
According to
300s
model
According to
60s
model
According to
120s
model
According to
60s
model
According to
600s
model
be