5. Commissioning, operation
- After the level sensor has been mounted, the float should be
reattached within the inside of the tank (pay attention to the
mounting position!).
- Secure the float limitation  again at the marked point.
5.4 Electrical connection
The electrical connection must only be made by qualified skilled
personnel.
Wire the level sensor in accordance with the connection diagram of
the electrical output (see product label). The connection terminals are
appropriately marked.
Electrical output
3-wire potentiometer
circuit
Current output signal
Voltage output signal
Seal the cable bushing  at the connection housing  (see figure in
chapter 5.3 „Mounting").
WIKA operating instructions models RLT
Connection diagram
GN
BN
WH
+
R
I
R
U
4 ... 20 mA
A
DC 12 ... 32 V
+
12...32 V DC
S
-
EN
0...10 V
U
0...5 V
13