1.
Move lift table on pallet to desired location using
a forklift or suitable lifting device. Installation area
should be clean and have good general lighting.
(See Figure 1)
Figure 1
2. In the lowered position, screw in lifting lugs through
the holes in the top of the lift table platform.
(See Figure 2)
Figure 2
3. Thread a lifting strap through each lifting lug.
(See Figure 3)
Figure 3
Lifting Straps
PAGE 2 OF 17
INSTALLATION
4. Using a forklift or suitable lifting device, raise the
lift table using the lifting straps, remove pallet from
beneath lift table and set lift table down into desired
location. Once set, remove lifting lugs from the lift
table.
5. Locate the separate box that contains the hand
control. This box is located under the primary
packaging material at the end of the base frame.
Remove the hand control with the control cord from
the box. (See Figure 4)
NOTE: The power cord attached to the base
frame is for use with a conventional 120 volt,
(20 amp) receptacle.
6. Insert plug into suitable receptacle.
7.
Using the hand control, press the "Up" button to raise
the table to its maximum raised height. (See Figure 5)
Figure 5
8. Run the table up and down several times to
remove any air that may have been trapped in
the hydraulic system during shipment.
Control Cord
Disconnect Plug
Hand Control
Emergency Stop
Power
Up
Down
Figure 4
0323 IH-10646