USER MANUAL SPIKA
The air cooled SPIKA MS (modular) ice makers take the air through the back section and drive it off through the two
lateral louvers. In the case it is not possible to respect the minimum distances recommended (see the picture in point 3)
for these machines we recommend to install a water cooled unit.
The location must allow enough clearance for water, drain and electrical connections in the rear of the ice machine. It is
important that the water inlet piping do not pass near sources of heat so as not to lose ice production.
(2) LEVELING THE ICE MACHINE
Use a level on top of ice machine in order to ensure the equipment is perfectly leveled.
Only for SPIKA NG (undercounter) machines:
Screw the leveling legs onto the bottom of the ice machine as far as possible.
Move the machine into its final position.
Use a level on top of the ice machine. Turn each foot as necessary to level the ice machine from front to back and side
to side.
NOTE: An optional 3 1/2'' (90mm) caster assembly is available for use in place of the legs. Installation instructions are
supplied with the casters.
(3) MINIMUM DISTANCE TO OBSTACLES
The minimum clearance values you can see below are recommended for efficient operation and servicing.
UNDERCOUNTER MODELS
MODULAR MODELS
4'' (10cm)
6'' (15cm)
6'' (15cm)
6'' (15cm)
FRONT
6'' (15cm)
FRONT
4'' (10cm)
29,5'' (75cm)