Sulzer CA 441 Guia De Instalacion página 95

Ocultar thumbs Ver también para CA 441:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 52
1.5.3 CA 443
Book_81307110_CA44x.indb 95
Book_81307110_CA44x.indb 95
Produktet måler av løpende forbruk, faseavvik og inngangsspenning for en pumpe eller en kom-
plett stasjon.
If pump is operated from a frequency converter, special precautions are required.
The high electric noise level can distort electrical readings, especially phase timing readings are
sensitive to switch transients from frequency converter.
Turn off all phase related alarms and dry run detection in PC 441 and ensure PC 441 firmware ver-
sion is V.1.42 or later
Normal current transformers operate from 45-60 Hz and must be placed on mains line input to
frequency converter.
Use only mains phase (voltage) missing alarm for pump protection (blocking).
To avoid conducted electrical noise in cabinet, follow best practices and manufacturer EMC compli-
ance recommendation when installing frequency converters. Use shielded cables. Ensure mains
and motor cables are separated from signal cables in cabinet.
General precautions:
If CA 443 for P1 also is used for mains monitoring, L1, L2 and L3 voltage inputs must be connected
before pump circuit breaker.
Tabell 9. CA 443 merkeytelser
Inngang
Spenning
30 - 300 V AC ± 5,0 V AC
0 - 5 A ± 0,1 A AC faseendring 0 -
Strøm
90 grader ± 1,5 grader
Tabell 10. Tilkoblinger på bunnsiden
Dir.
Signal
#
Sensor 1
6
Sensor 2
7
Sensor 3
8
GND
9
a Sensor 4
10
b GND
11
a Sensor 5
12
b GND
13
a Sensor 6
14
b GND
15
Tabell 11. CA 443 LED indicators from PC 441 firmware 1.42
LED
Indication
Mains monitor (0 or 1)
1
Phase 1
Voltage missing
2
Phase 2
Voltage missing
3
Phase 3
Voltage missing
4
Warning
Alarm wrong phase order
Alarm phase missing
Pending high voltage
Pending low voltage
Pending unbalanced voltage
Pending high freq.
Pending low freq.
Område
Kommentar
Ved høyere spenninger brukes
en spenningstransformator
Bruk alltid strømtransformator
Description
AC inngangsspenning L1
AC inngangsspenning L2
AC inngangsspenning L3
Spenningsinngangsreferanse
Strøm transformatorinngang1
Strøm transformatorinngang 2
Strøm transformatorinngang 3
Pump monitor (1-4)
Voltage missing
Voltage missing
Voltage missing
Alarm phase current missing
95
CA 443
NO
05/04/2022 12:18:12
05/04/2022 12:18:12
loading

Este manual también es adecuado para: