2
2.1 Technical data CA 44x
Book_81307110_CA44x.indb 13
Book_81307110_CA44x.indb 13
TECHNICAL DATA
Device
CA 441
Ambient operation
temperature
Ambient storage
temperature
Degree of protection
Housing material
Mounting
Installation category
Pollution degree
Flame rate
Power rating current
Transformers CA443
Dimension HxWxD
Humidity
Power supply
Power consumption
Inputs
4 channels
4 leakage
ABS
Modes
mode
Approx range
0-220 kΩ
Note
Input mode
can be set
individually for
each channel.
Outputs
Communication ports
Field Bus
Max altitude
Approval
CA 442
-20 to +50°C (-4 to +122°F)
-30 to +80°C (-22 to +176°F)
IP 20, NEMA: Type 1
PPO and PC
DIN Rail 35 mm
CAT II
2
V0 (E45329)
86 x 70 x 58 mm (3.39 x 2.76 x 2.28 inch)
Plug in connectors will add 2x 9.5 mm (0.375 inch) to 'H'
0-95 % RH non condensing
9-34 VDC SELV or Class 2
< 2.0 W
5 channels
4 temp, 1 low dc current
Xylem
PTC
Pt100
0/4-20 mA
mode
mode
mode
Int. res 136
Ω. PTC
protected
-20 -
0-10
0-10
+180ºC
0-20 mA
kΩ
kΩ
(-4ºF - +
356 ºF)
Input mode can be set
individually for each channel.
None
1 CAN port
2000 m
13
CA 443
1.0 - 5.0 VA
Class 1
6 channels
3 voltage, 3
ac current
Voltage
Current
30-300
0-5A AC
VAC
All current
measuring
is done
through
current
trans-
formers
1 galvanic
isolated CAN port
EN
05/04/2022 12:13:37
05/04/2022 12:13:37