INSTALLATION
Typical Installation
4 ft (1.2 m) above floor level
In Flow
Scum
Physical Installation
Risk of damage to pump or other equipment.
• Support pump and piping when assembling and when installed. Failure to do so may cause piping to break, pump
to fail, motor bearing failures, etc.
• Do not install the check valve in a vertical position, as solids may settle in the valve and prevent the valve from
opening on start-up. For best performance of the check valve when handling solids, install it in a horizontal posi-
tion or at an angle of no more than 45°.
1. Install the pump in the center of a suitable gas-tight basin that is at least 18-inches diameter and
24-inches deep.
• Provide adequate room for future servicing, protection from freezing temperatures, flooding,
and equipment drainage.
• Never place the pump directly on clay, earth, or gravel surfaces.
• Ensure sump is clean and free of nails, gravel, string, cloth, or other debris before installing.
IMPORTANT: Do not attempt to restrict the intake side of the pump.
2. Connect discharge piping, using pipe joint compound at all connections.
• The discharge pipe should be as short as possible and contain as few elbows as possible.
• Ensure piping is the same diameter as the discharge port.
• If reduced flow rates are required, place a valve on the discharge side of the pump.
3. Install a union in the discharge line just above the basin cover.
4. Install a free flow check valve in the discharge line that will easily pass
Outlet minimum
Float switch piggyback plug
(automatic models only)
Septic Tank Chamber
Sediments
Pump Power Cord
Tank/basin
minimum size 1.5 ft (.5 m)
Minimum 4" (10.2 cm)
free length of cable
Baffle
Air Relief Bleed Hole
INSTALLATION
Typical Installation
Discharge
Tank Vent
Check Valve
Union
Discharge Pipe
2 ft
(.6 m)
11
-inch solids.
/
16
START
STOP
3