CIAT HELIOTHERME H4000 Manual De Instrucciones página 36

Idiomas disponibles

Idiomas disponibles

14 -
CONTROL UNITS
HEE 1-PH BOX (for HELIOTHERME
Thank you for purchasing the "HEE 1-PHASE BOX" electronic control solution for 
HELIOTHERME
 or DESTRATIFIER units fitted with HEE 
®
1-PHASE motors. Up to 6 HELIOTHERME
or 3 HELIOTHERME
 + 3 DESTRATIFIER units can be controlled using a single box. 
®
This box allows the following:
• Proportional variation of the supply air speed of the HEE 1-phase fan motor assembly (0-10V FMA) 
according to the heating requirements of your building.
Heat or cool as precisely as possible in accordance with your needs.
• Supply water to one or more heat exchangers according to your building's heat requirements (available with the optional valve kit).
Control your supply air temperature to improve comfort levels and maintain the range of the air streams.
• Choose between fresh air only or mix with frost protection via the servomotor to be installed on the 2-channel mixing box with
built-in filter (available with the fresh air kit damper servomotor + frost protection thermostat kit) or 100% recirculated air.
Adjust the fresh air rates in your building to meet current requirements or based on room occupancy levels (built-
in timer).
• The internal timer can be configured on a weekly basis using 3 operating modes (Comfort, Eco, Frost protection), allowing 
you to make environmentally-sound use of your air heaters.
The heating requirements of your building will depend on its occupancy level.
• Centralised management of the HELIOTHERME
units to be controlled (one HEE BOX master or slave unit controls 6 HELIOTHERME
TPL).
The display shows the operating status of each individual HELIOTHERME
risk of frost, etc.)
• All of the protective devices necessary to connect 6 units (HELIOTHERME
Plug & Play solution
• A remote on/off control is available as well as a two separate fault summaries. Possibility to communicate via ModBus, JBUS 
or Bacnet IP.
Networked solution
Refer to the instruction manual supplied in the packaging of your HEE 1-PH BOX for further information or contact your CIAT
agent.
3-speed HEE THERMOSTAT
• Functions
The HEE control includes a temperature selector (range from 10°C to 30°C) that maintains the room temperature at the selected
value.
• FAN operation
The user can use the fan speed selector button to set the fan's operating mode to manual or automatic.
In manual mode, three types of speed can be selected (low, mid, high) depending on the requirements or energy saving
mode. This energy saving mode is particularly useful for air conditioning in rooms at night or rooms left unoccupied for long
periods.
In automatic mode, the fan speeds are controlled by a microprocessor housed in the control unit, according to the temperature
selected. (see table below. (3 speeds possible depending on the HELIOTHERME
Shunt 6
Shunt 7
Closed
Closed
Closed
Closed
Closed
Open
Closed
Open
Open
Closed
Open
Closed
Open
Open
Open
Open
H4000 HELIOTHERME
®
or destratifier units fitted with HEE 1-PHASE motors)
®
®
 or 6 DESTRATIFIER units 
 units via the master controller allowing up to 10 HEE 1-PHASE BOX slave 
®
Shunt 8
LOW
Closed
2 V
Open
2 V
Closed
6 V
Open
2 V
Closed
8 V
Open
5 V
Closed
4 V
Open
3 V
unit (fresh air or return air, motor fault,
®
or TPL) as well as 6 valve kits.
®
model)
®
MID
HIGH
6 V
10 V
4 V
6 V
8 V
10 V
3 V
4 V
9 V
10 V
6 V
7 V
6 V
8 V
6 V
9 V
EN-36
     
units or 3 HELIOTHERME
®
Heliotherm model
Heating
Cooling
H4300 / H4450
H4500 / H4630
-
-
-
H4400 / H4450
-
H4400 / H4630
H4500
H4350
units + 3
®
-
-
-
-
H4300
H4350
loading