Uniteck UNIPOWER 150.12Q Manual De Instrucciones página 36

Ocultar thumbs Ver también para UNIPOWER 150.12Q:
Idiomas disponibles

Idiomas disponibles

EN
TROUBLESHOOTING
UNIPOWER 2000.12Q and 2000.24Q
Troubleshooting
Unipower does not deliver
current anymore
+ Sound alarm on the inverter
+ The remote display indicates
"Err Low"
Unipower does not deliver
current anymore
+ Alarm
+ The remote display indicates
"Err high"
Unipower does not deliver
current anymore
+ alarm
+ The remote display indicates
"Over Load"
Unipower does not deliver
current anymore
+ Alarm
+ The remote display indicates
"Over Temp"
36/68
Causes
Discharged battery
24V>230V inverter:
battery not suitable (12V
instead of 24V)
Battery/inverter connection is
defective
Battery overvoltage
Overconsumption
Thermal protection: the
inner temperature of the
inverter is above 45°C
.
WWW
UNITECK
Remedies
Recharge your battery or replace it,
if it is defective.
Replace your 12V battery with a 24V
battery.
Check your connections (cables,
terminals, tightening...)
Check that the battery voltage is
compatible with the inverter.
Replace the battery if it is defective.
Recharge your battery.
Unipower will restart when the
battery voltage will be acceptable.
Replace the battery if necessary.
Stop the consuming devices. Let the
inverter cool down and improve the
ventilation.
.
FR
loading