TROUBLESHOOTING
TROUBLESHOOTING
UNIPOWER 1000.12Q / UNIPOWER 1000.24Q
Troubleshooting
Alarm
Unipower does not deliver current
anymore
Causes
Discharged battery
24V>230V inverter:
battery not suitable (12V
instead of 24V)
Battery/inverter connection is
defective
The inverter is off
Battery connection problem
Thermal protection: the inner
temperature of the inverter is
above 45°C
Overconsumption
Inverter/devices to supply
connection problem
.
WWW
UNITECK
Remedies
Recharge your battery or
replace it, if it is defective.
Replace your 12V battery with
a 24V battery.
Check your connections
(cables, terminals,
tightening...)
turn it on again.
Check your battery
connections.
Stop the consuming devices. Let
the inverter cool down and
improve the ventilation.
Recharge your battery.
Unipower will restart when the
Battery voltage will be
acceptable.
Replace the battery if
necessary.
Check the connections.
.
FR