III.General Warnings
1. After use, turn off the unit and disconnect from power.
2. If any leaks or malfunctions are found, turn the unit off immediately and call a service technician to
inspect and/or repair it.
3. The temperature of this appliance is between 40-90°C. It is recommended that the usual operating
temperature is 60-85 °C.
4. This equipment should be installed in an environment with good ventilation conditions of ≤45 °C.
5. The equipment should be well grounded to meet safety requirements.
IV.Installation Warnings
1. Check to see if the equipment is set up to operate at the voltage and frequency with which it will be
powered.
2. If the power cord is damaged, it should be replaced with an oil-resistant, YCW or YZW cord with a two-
color yellow-green ground wire.
3. The equipment should be placed in a stable place, the distance between the surface of the equipment
and flammable materials should be ≥ 50cm
4. The fixed wiring connected to the power cord of this equipment should have an open gap (contact
opening distance of 3mm or more) and a leakage protection switch disconnected on all poles according to
the wiring rules. It is recommended that a ground fault circuit interrupter be installed. Do not stack debris
in front of the switch for ease of operation.
5. There is a grounding bolt behind the furnace body, and copper core wire not less than 1.5mm2 is used to
reliably connect with the ground wire that meets safety standards.
10