CONNECTOR SPECIFICATION FOR WIRE-END SENSOR
SMARTFEEDs are equipped with a connector for a wire end sensor on the rear panel (I-7).
The plug is an M8 / 3-pole connector.
Voltage: 24 VDC
Max current: 250mA
CONNECTOR SPECIFICATION FOR COLLISION SENSOR
SMARTFEED M-4 :
The SMARTFEED M-4 is equipped with a collision sensor connector on the front panel (I-4).
The plug is an M8 / 3-pole connector.
Voltage: 24 VDC
Max current: 250mA
SMARTFEED MB-PP :
The SMARTFEED MB-PP is equipped with a collision sensor connector on the front panel (I-4).
The connector is a 24-pin plug.
The collision input operates on 24V.
TORCH COMPATIBILITY
• The SMARTFEED M-4 is compatible with all standard robotic torches (excluding Push-Pull) with a EURO connection.
• The SMARTFEED MB-PP can accommodate 3 types of torches:
- Standard robotic torches without Push-Pull (EURO connection), all brands.
- Push-Pull DC robotic torches (EURO connection / max. permissible voltage 42V / without encoder), all brands.
- Push-Pull BRUSHLESS robotic torches (EURO connection / max voltage 42V / 500pts encoder).
Compatible with the BINZEL MPP OA PUSH PULL torch.
Other brands or references, please consult us before use.
The configuration of the torch type can be done in 2 different ways (see the following pages):
- Changing the configuration of a DIP SWITCH on the circuit board (requires opening the product, see page 59-60).
- Pin grounding in the torch connector during wiring by the customer.
SMARTFEED M-4 / MB-PP
4 (N/O)
3 (-)
(view from wire
feeder)
4 (N/O)
3 (-)
(view from wire
feeder)
24
(view from wire
feeder)
Pin
Product name
Function
13
GND
Collision sensor
14
24 VDC
(dry contact between 24 Vdc and
Collision or
signal)
15
Signal
EN
1 (+)
1 (+)
1
15