Haier HATSI120CBS6BVOC Instalación página 9

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 11
Control panel
To select the hood functions, simply touch the controls.
T1
T2
T3
T4
T5
T6
T7
T1 = Motor OFF key (stand by)
T2 = Speed selection key (extraction power) low. The key flashes if delayed hood switch-off is activated (only for models
with remote control).
T3 = Speed selection key (extraction power) medium. The key flashes if delayed hood switch-off is activated (only for
models with remote control).
T4 = Speed selection key (extraction power) high. The key flashes if delayed hood switch-off is activated (only for models
with remote control).
T5 = Speed selection key (suction power) intensive - it lasts 5 minutes after which it switches back to medium speed
(extraction power) or it switches off if delayed hood switch-off is activated (only for models with remote control). The key
flashes in both cases to indicate the speed timer.
T6 = Light ON/OFF key. Short press to switch illumination of the cooking hob on or off.
T7 = Automatic operation (sensor).
Filter saturation indicators (T5)
At regular intervals, the hood signals the need to perform maintenance on the filters.
Key (T5) on with steady light: the grease filter requires maintenance.
Key (T5) on with flashing light: the activated carbon filter requires maintenance.
Note: The filter saturation indicator is visible within on first minute after switching off the hood; the saturation indicators
must be reset within this time.
Resetting the filter saturation indicators (T5)
Press and hold key (T5).
Activating the activated carbon filter saturation indicator (T5).
Note: this operation must be performed with the hood off.
This indicator is normally deactivated; press and hold key (T5) to activate the function: the key will light up steadily.
To deactivate the function, press and hold key (T5): the key will start flashing.
Automatic operation (sensor) (T7)
Press key (T7) (the central LED (T7) lights up white). The hood will switch on at the most suitable speed based on the
fumes detected by the sensor the hood is equipped with.
Adjusting the parameters for automatic operation
Note: All of the calibration, selection, adjustment and logical connection operations described below are possible with the
hood switched off (OFF).
The parameters are adjusted automatically each time the hood is reconnected to the mains (e.g. first installation or after a
power failure) or manually.
Manual adjustment
To be performed when automatic operation is unsatisfactory and when normal environmental conditions persist in the
kitchen.
Manual adjustment includes:
• Hood calibration.
• Hob selection (gas - induction or electric).
Hood calibration (T7).
Press and hold key (T7), all of the LEDs of the key will flash "darker" to indicate that calibration has started; the calibration
process will take about 5 minutes.
Hob selection (gas - induction or electric).
8
Tabla de contenido
loading

Tabla de contenido