Storage And Transport; Maintenance; Electrical Connection - Scheppach NTS30 Premium Traducción Del Manual De Instrucciones Original

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 52
Empty the stainless steel container (8) after each use:
After opening the screw cap (7) to drain out the liquids,
the liquid collected can be drained out. Residual liquid
remains in the stainless steel container (8).
To remove residual liquid, take off the machine head
(2) by releasing the locking hooks (4) from the stainless
steel container (8). Pour out the liquid residue. Clean
the container with a damp cloth.
• Replace paper filter bag when full
• Always keep the device clean. Do not use cleaning
agents or solvents.
• Keep the ventilation slots clean and free of dirt and
dust.
• Clean the device only with a soft brush or a damp
cloth.
• Clean the foam filter (b) with a little soap and running
water and then leave it to air dry.

11. Storage and Transport

Store the device and its accessories in a dark, dry and
frost-proof place that is inaccessible to children. The
optimum storage temperature is between 5 and 30˚C.
Store the electrical tool in its original packaging.
Cover the electrical tool in order to protect it from dust
and moisture.
Store the operating manual with the electrical tool.
• Wind the mains cable (3) around the top cable hold-
er (12). (Fig. P)
• There are four recesses on the top side of the cast-
er mounting base (6) for storing the floor nozzle (e),
the joint nozzle (f) and the metal extension tube (g).
(Fig. Q)
• The remaining accessories can be stored in the
stainless steel container (8).

12. Maintenance

Warning!
Disconnect the mains plug before carrying out any
maintenance work.
Connections and repairs
Connections and repairs of electrical equipment may
only be carried out by an electrician.
Please provide the following information in the
event of any enquiries:
• Type of current for the motor
• Machine data - type plate
• Motor data - type plate
22 | GB
Service information
Please note that the following parts of this product are
subject to normal or natural wear and that the following
parts are therefore also required for use as consuma-
bles. Wear parts*: Foam filter, Paper filter bag, Folded
filter for dry vacuuming
* Not necessarily included in the scope of delivery!
Spare parts and accessories can be obtained from our
service centre. To do this, scan the QR code on the
cover page.

13. Electrical connection

The electrical motor installed is connected and
ready for operation. The connection complies with
the applicable VDE and DIN provisions.
The customer's mains connection as well as the
extension cable used must also comply with these
regulations.
Damaged electrical connection cable
The insulation on electrical connection cables is of-
ten damaged.
This may have the following causes:
• Passage points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the
wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables with the marking „H05VV-F".
The printing of the type designation on the connection
cable is mandatory.
www.scheppach.com