English
Operating temperature, protection of the instruments and information about storage
Conditions of use (°C/%RH/m): from 0 to +50 °C; in non-condensing conditions. From 0 to 2000 m.
Protection: IP65
Storage temperature: from -10 to +60 °C.
Dimensions
Ambient model
41 mm
41 mm
41 mm
46 mm
46 mm
Model with terminal block
46 mm
Symbols used
For your safety and in order to avoid any damage of the device, please follow the procedure described in
this document and read carefully the notes preceded by the following symbol:
The following symbol will also be used in this document, please read carefully the information notes
indicated after this symbol:
Connections
1.
Terminal block (only for model with
terminal block)
2.
Switch
3.
LCC-S software connection
4.
Output terminal block
5.
Power supply terminal block
6.
Cable gland
Connection of a Pt100 probe
on terminal block
Ambient model /
(1)
or IP20
(2)
(1)
41 mm
90 mm
90 mm
90 mm
Ø13 mm
46 mm
46 mm
90 mm
46 mm
90 mm
90 mm
90 mm
46 mm
46 mm
(3)
90 mm
46 mm
46 mm
90 mm
46 mm
1
2
46 mm
-
Display/regulator/PLC
passive type
Inside the front housing
Duct and air tight models, model with terminal block and piping contact model /
(2)
Temperature transmitter
150 mm
46 mm
Ø6 mm
Duct model, stainless steel probe
90 mm
90 mm
112 mm
46 mm
46 mm
Ø6 mm
Ø6 mm
Ø6 mm
112 mm
90 mm
112 mm
90 mm
Airtight ambient model
112 mm
90 mm
46 mm
GND VT
-
+
-
+
90 mm
3
4
5
6
7
90 mm
4 wires
+
-
+
V
Power supply
24 Vdc
or
N L
6 7
1
2
N
L
Power supply 24 Vac
4 wires
Classe II
Measuring probe
Warning: if a 2-wire Pt100 probe is used,
carry out a shunt between 2 and 2'.
1
2
2'
(3)
90 mm
(2)
Stainless steel probe technical
90 mm
specifications (duct model): Ø6 mm
90 mm
contact tip; available lengths: 100 mm,
150 mm, 200 mm, 250 mm or 300 mm.
90 mm
GND VT
-
+
1
2
3
4
5
-
+
V
Display/regulator/PLC
passive type
3
3 wires
Removable front face
Fixed back housing
Several probes available in option
-
+
6
7
3 wires
+
Power supply 24 Vdc
-
or
GND VT
-
+
N
L
4 5 6
7
4
5
N
6
Power supply 24 Vac
Classe II
Tabla de contenido